{"id":952,"date":"2026-10-13T09:03:46","date_gmt":"2026-10-13T09:03:46","guid":{"rendered":"https:\/\/swme.ae\/blog\/?p=952"},"modified":"2026-10-13T09:03:46","modified_gmt":"2026-10-13T09:03:46","slug":"ue-400-series-pressure-and-temperature-switch-uae","status":"publish","type":"post","link":"https:\/\/swme.ae\/blog\/ue-400-series-pressure-and-temperature-switch-uae\/","title":{"rendered":"UE 400 Series Pressure and Temperature Switch Suppliers in UAE"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"952\" class=\"elementor elementor-952\">\n\t\t\t\t<div class=\"elementor-element elementor-element-05d0f2f e-flex e-con-boxed e-con e-parent\" data-id=\"05d0f2f\" data-element_type=\"container\" data-e-type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f7ef0a3 elementor-widget elementor-widget-html\" data-id=\"f7ef0a3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"html.default\">\n\t\t\t\t\t<!DOCTYPE html>\r\n<html lang=\"en\">\r\n<head>\r\n<meta charset=\"UTF-8\">\r\n<title>UE 400 Series Pressure and Temperature Switch Suppliers in UAE<\/title>\r\n<style>\r\n  :root{\r\n    --navy:#0d2b45;\r\n    --teal:#0d8a8a;\r\n    --teal-dark:#08615f;\r\n    --bg-light:#f4f8f9;\r\n    --card-bg:#ffffff;\r\n    --border:#dbe6e8;\r\n    --text:#22333b;\r\n    --muted:#5c6b73;\r\n  }\r\n  *{box-sizing:border-box;}\r\n  body{\r\n    font-family:\"Segoe UI\",Arial,Helvetica,sans-serif;\r\n    background:var(--bg-light);\r\n    color:var(--text);\r\n    margin:0;\r\n    padding:0;\r\n    line-height:1.7;\r\n  }\r\n  .wrap{max-width:860px;margin:0 auto;padding:32px 20px 60px;}\r\n  .eyebrow{\r\n    text-transform:uppercase;letter-spacing:1.5px;font-size:13px;\r\n    color:var(--teal-dark);font-weight:700;margin-bottom:8px;\r\n  }\r\n  h1{color:var(--navy);font-size:28px;line-height:1.3;margin:0 0 12px;}\r\n  .byline{color:var(--muted);font-size:14px;margin-bottom:28px;}\r\n  h2{color:var(--navy);font-size:22px;margin-top:44px;border-left:5px solid var(--teal);padding-left:14px;}\r\n  h3{color:var(--navy);font-size:17px;margin-top:22px;}\r\n  p{margin:14px 0;}\r\n  a{color:var(--teal-dark);text-decoration:none;border-bottom:1px solid var(--teal);}\r\n  a:hover{color:var(--navy);border-color:var(--navy);}\r\n\r\n  .stat-bar{\r\n    display:flex;gap:14px;flex-wrap:wrap;\r\n    background:var(--navy);border-radius:12px;padding:22px;margin:26px 0;\r\n  }\r\n  .stat{flex:1;min-width:150px;text-align:center;color:#fff;}\r\n  .stat .num{font-size:24px;font-weight:800;color:#5fe0d6;display:block;}\r\n  .stat .label{font-size:13px;color:#c9d8e0;margin-top:4px;display:block;}\r\n\r\n  .feature-grid{display:grid;grid-template-columns:1fr 1fr;gap:14px;margin:22px 0;}\r\n  @media (max-width:680px){.feature-grid{grid-template-columns:1fr;}}\r\n  .feature-card{\r\n    background:var(--card-bg);border:1px solid var(--border);border-radius:12px;\r\n    padding:18px;border-top:4px solid var(--teal);\r\n  }\r\n  .feature-card h3{margin-top:0;font-size:16px;}\r\n  .feature-card p{margin:8px 0 0;font-size:14.5px;}\r\n\r\n  table.compare{\r\n    width:100%;border-collapse:collapse;margin:20px 0 10px;font-size:14.5px;\r\n    background:var(--card-bg);border-radius:10px;overflow:hidden;\r\n    box-shadow:0 2px 10px rgba(13,43,69,0.06);\r\n  }\r\n  table.compare th{background:var(--teal-dark);color:#fff;text-align:left;padding:12px 14px;font-size:13.5px;}\r\n  table.compare td{padding:12px 14px;border-bottom:1px solid var(--border);vertical-align:top;}\r\n  table.compare tr:last-child td{border-bottom:none;}\r\n  table.compare tr:nth-child(even) td{background:#f7fbfb;}\r\n  table.compare td.tech{font-weight:700;color:var(--navy);}\r\n  .tablewrap{overflow-x:auto;}\r\n  .note{font-size:13px;color:var(--muted);margin-top:6px;}\r\n\r\n  details.criterion{\r\n    background:var(--card-bg);border:1px solid var(--border);border-radius:10px;\r\n    margin:12px 0;padding:14px 18px;\r\n  }\r\n  details.criterion summary{\r\n    cursor:pointer;font-weight:700;color:var(--navy);font-size:16px;\r\n    list-style:none;position:relative;padding-right:24px;\r\n  }\r\n  details.criterion summary::-webkit-details-marker{display:none;}\r\n  details.criterion summary::after{\r\n    content:\"+\";position:absolute;right:0;top:0;color:var(--teal-dark);font-size:18px;font-weight:800;\r\n  }\r\n  details.criterion[open] summary::after{content:\"\\2013\";}\r\n  details.criterion p{margin-top:10px;color:var(--text);font-weight:400;font-size:15px;}\r\n\r\n  ul.app-list{padding-left:0;list-style:none;}\r\n  ul.app-list li{\r\n    background:var(--card-bg);border-left:4px solid var(--teal);\r\n    padding:10px 16px;margin:8px 0;border-radius:0 6px 6px 0;\r\n    box-shadow:0 1px 4px rgba(13,43,69,0.05);\r\n  }\r\n\r\n  .cta-buttons{display:flex;gap:14px;flex-wrap:wrap;margin:26px 0;}\r\n  .btn{display:inline-block;padding:13px 22px;border-radius:8px;font-weight:700;text-decoration:none;border:none;font-size:15px;}\r\n  .btn-whatsapp{background:#25D366;color:#fff;border-bottom:none;}\r\n  .btn-call{background:var(--navy);color:#fff;border-bottom:none;}\r\n\r\n  .inquiry-form{background:var(--card-bg);border:1px solid var(--border);border-radius:12px;padding:26px;margin-top:20px;}\r\n  .inquiry-form h3{margin-top:0;}\r\n  .inquiry-form label{display:block;font-size:13px;font-weight:700;color:var(--navy);margin:14px 0 6px;}\r\n  .inquiry-form input,.inquiry-form textarea{\r\n    width:100%;padding:10px 12px;border:1px solid var(--border);border-radius:6px;\r\n    font-size:14px;font-family:inherit;\r\n  }\r\n  .inquiry-form textarea{min-height:90px;resize:vertical;}\r\n  .inquiry-form .submit-btn{\r\n    margin-top:18px;background:var(--teal-dark);color:#fff;border:none;\r\n    padding:12px 26px;border-radius:8px;font-weight:700;cursor:pointer;font-size:15px;\r\n  }\r\n  .required{color:#c0392b;}\r\n<\/style>\r\n<\/head>\r\n<body>\r\n<div class=\"wrap\">\r\n\r\n  <div class=\"eyebrow\">Product Guide \u2022 Pressure and Temperature Switches<\/div>\r\n  <h1>UE 400 Series Pressure and Temperature Switch Suppliers in UAE<\/h1>\r\n  <div class=\"byline\">SWME Control Systems Trading LLC \u2022 United Electric Controls \u2022 October 2026<\/div>\r\n\r\n  <p>Every process plant needs a dependable way to raise an alarm or shut down equipment when pressure or temperature moves outside safe limits. The 400 Series Pressure and Temperature Switch from United Electric Controls (UE) does this job with a mechanical switch that works on its own, without depending on the control system.<\/p>\r\n<figure style=\"text-align:center; margin:30px 0;\">\r\n    <img decoding=\"async\" src=\"https:\/\/swme.ae\/blog\/wp-content\/uploads\/2026\/10\/400-Series-Pressure-and-Temperature-Switch.webp\"\r\n        alt=\"400 Series Pressure and Temperature Switch\"\r\n        title=\"400 Series Pressure and Temperature Switch\"        \r\n        style=\"max-width:100%; height:auto; border-radius:8px; box-shadow:0 4px 12px rgba(0,0,0,0.12);\">      \r\n<\/figure>\r\n  <p>The 400 Series Pressure and Temperature Switch is FM approved and built to <a href=\"https:\/\/en.wikipedia.org\/wiki\/NEMA_enclosure_types\" target=\"_blank\" rel=\"noopener\">NEMA 4X<\/a> construction requirements. It gives you one, two, or three independent switch outputs in a single unit. It also comes with a wide choice of ranges, sensors, and process connections, so one product family covers pressure, vacuum, differential pressure, and temperature duty.<\/p>\r\n\r\n  <p>As one of the UE 400 Series suppliers in UAE, SWME Control Systems Trading LLC supplies this range across the UAE, Qatar, Oman, Kuwait, and Bahrain. This guide explains the features, model families, options, and certifications you need to know before you specify one.<\/p>\r\n\r\n  <div class=\"stat-bar\">\r\n    <div class=\"stat\"><span class=\"num\">3<\/span><span class=\"label\">Independent SPDT switches available in one unit<\/span><\/div>\r\n    <div class=\"stat\"><span class=\"num\">15 A<\/span><span class=\"label\">Standard switch rating at 125, 250, and 480 VAC<\/span><\/div>\r\n    <div class=\"stat\"><span class=\"num\">NEMA 4X<\/span><span class=\"label\">Die cast aluminum enclosure construction<\/span><\/div>\r\n  <\/div>\r\n\r\n  <h2>What Is the 400 Series Pressure and Temperature Switch?<\/h2>\r\n  <p>The 400 Series is an electromechanical <a href=\"https:\/\/www.instrumentationblog.in\/what-is-a-pressure-switch\/\" target=\"_blank\" rel=\"noopener\">pressure switch<\/a>. In pressure models, a sensor such as a bellows, diaphragm, or piston moves when pressure changes. In temperature models, a bulb or immersion stem does the same job. That movement operates a microswitch at the setpoint you choose.<\/p>\r\n  <p>Because the switch is mechanical, it can operate independently of the control system. It switches reliably when called upon, and it is free from communication errors or cyber concerns. For example, a low pressure switch on a pump discharge line can trip the pump starter circuit directly, even when the PLC is offline.<\/p>\r\n\r\n  <h2>Key Features of the 400 Series Pressure and Temperature Switch<\/h2>\r\n  <div class=\"feature-grid\">\r\n    <div class=\"feature-card\">\r\n      <h3>Up to Three Independent Switches<\/h3>\r\n      <p>Low limit and high limit alarm and safety shutdown can be handled with one, two, or three independent switches. On most models, the switches can be separated by up to 100% of range.<\/p>\r\n    <\/div>\r\n    <div class=\"feature-card\">\r\n      <h3>Simple Installation and Adjustment<\/h3>\r\n      <p>The wiring compartment has ample access. You set the setpoint with a reference dial or a calibrated gauge, depending on the type you choose.<\/p>\r\n    <\/div>\r\n    <div class=\"feature-card\">\r\n      <h3>Wide Application Versatility<\/h3>\r\n      <p>A variety of ranges, microswitches, sensors, and process connections lets you match the switch to the process instead of changing the process to suit the switch.<\/p>\r\n    <\/div>\r\n    <div class=\"feature-card\">\r\n      <h3>Replaces a Switch and a Gauge<\/h3>\r\n      <p>In <a href=\"https:\/\/www.instrumentationblog.in\/differential-pressure-switch-working\/\" target=\"_blank\" rel=\"noopener\">differential pressure switch<\/a> applications, the optional visual indicator (option M210) lets one device do the work of both a switch and a gauge.<\/p>\r\n    <\/div>\r\n    <div class=\"feature-card\">\r\n      <h3>Rugged Enclosure<\/h3>\r\n      <p>The enclosure is die cast aluminum with an epoxy powder coat, a gasket, and captive cover screws. It is built to NEMA 4X requirements and works in ambient temperatures from minus 40 to 71 \u00b0C.<\/p>\r\n    <\/div>\r\n    <div class=\"feature-card\">\r\n      <h3>Global Agency Certification<\/h3>\r\n      <p>All models are FM approved. Intrinsic safety certification is available for many regions, including the UAE through ECAS.<\/p>\r\n    <\/div>\r\n  <\/div>\r\n\r\n  <h2>Switch Types and Model Families<\/h2>\r\n  <p>The type code tells you what the switch measures, how many switches it has, and how you adjust the setpoint. The number 400 means one SPDT switch, 402 means two, and 403 means three.<\/p>\r\n  <div class=\"tablewrap\">\r\n  <table class=\"compare\">\r\n    <tr><th>Type<\/th><th>Measures<\/th><th>Switch Outputs<\/th><th>Setpoint Adjustment<\/th><\/tr>\r\n    <tr><td class=\"tech\">J400, J402, J403<\/td><td>Pressure and vacuum<\/td><td>One, two, or three SPDT<\/td><td>Internal hex screw<\/td><\/tr>\r\n    <tr><td class=\"tech\">H400, H402, H403<\/td><td>Pressure and vacuum<\/td><td>One, two, or three SPDT<\/td><td>Internal, with reference dial<\/td><\/tr>\r\n    <tr><td class=\"tech\">J400K, J402K<\/td><td>Differential pressure<\/td><td>One or two SPDT<\/td><td>Internal hex screw<\/td><\/tr>\r\n    <tr><td class=\"tech\">H400K, H402K<\/td><td>Differential pressure<\/td><td>One or two SPDT<\/td><td>Internal, with reference dial<\/td><\/tr>\r\n    <tr><td class=\"tech\">B400, B402, B403<\/td><td>Temperature, immersion stem<\/td><td>One, two, or three SPDT<\/td><td>Internal, with reference dial<\/td><\/tr>\r\n    <tr><td class=\"tech\">C400, C402, C403<\/td><td>Temperature, immersion stem<\/td><td>One, two, or three SPDT<\/td><td>Internal hex screw<\/td><\/tr>\r\n    <tr><td class=\"tech\">E400, E402, E403<\/td><td>Temperature, bulb and capillary<\/td><td>One, two, or three SPDT<\/td><td>Internal, with reference dial<\/td><\/tr>\r\n    <tr><td class=\"tech\">F400, F402, F403<\/td><td>Temperature, bulb and capillary<\/td><td>One, two, or three SPDT<\/td><td>Internal hex screw<\/td><\/tr>\r\n  <\/table>\r\n  <\/div>\r\n\r\n  <h2>Pressure Ranges, Sensors, and Wetted Materials<\/h2>\r\n  <p>Pressure models cover a very wide span. The lowest range starts at 0 to 2 inches of water column (model 440). The highest range reaches 500 to 6,000 psi (model 614). Each sensor style suits a different part of that span.<\/p>\r\n  <div class=\"tablewrap\">\r\n  <table class=\"compare\">\r\n    <tr><th>Sensor Style<\/th><th>Models<\/th><th>Wetted Materials<\/th><th>Range Highlights<\/th><\/tr>\r\n    <tr><td class=\"tech\">Bellows<\/td><td>126 to 164<\/td><td>Brass, nickel plated brass, zinc plated steel<\/td><td>30 inches Hg vacuum to 200 psi<\/td><\/tr>\r\n    <tr><td class=\"tech\">Welded bellows<\/td><td>S126B to S164B<\/td><td>Welded 316L SS<\/td><td>30 inches Hg vacuum to 200 psi<\/td><\/tr>\r\n    <tr><td class=\"tech\">Bellows<\/td><td>270, 274, 358 to 376<\/td><td>Phosphor bronze (270, 274) or welded 316L SS (358 to 376)<\/td><td>0 to 200, 300, and 500 psi<\/td><\/tr>\r\n    <tr><td class=\"tech\">Diaphragm<\/td><td>440 to 454, 550 to 555, 570 to 572<\/td><td>Buna N and aluminum; Teflon, Viton, and 316L SS; or 316L SS and Viton<\/td><td>Very low ranges up to 100 psi<\/td><\/tr>\r\n    <tr><td class=\"tech\">Large diaphragm<\/td><td>520 to 525, 530 to 535<\/td><td>Buna N and epoxy coated aluminum (520 to 525); welded 316L SS (530 to 535)<\/td><td>Inches of water column, up to 250 inches<\/td><\/tr>\r\n    <tr><td class=\"tech\">Piston<\/td><td>610 to 614<\/td><td>303 SS and Buna N<\/td><td>100 to 6,000 psi<\/td><\/tr>\r\n  <\/table>\r\n  <\/div>\r\n  <p>The piston models have an over range rating of 6,000 psi and a proof pressure of 10,000 psi. UE does not recommend them for gas service, because the O ring seal can dry out and allow the medium to bleed into the atmosphere.<\/p>\r\n  <p class=\"note\">Proof pressure is the maximum pressure the sensor can see without permanent damage. The unit may need recalibration afterward.<\/p>\r\n\r\n  <h2>Differential Pressure and Temperature Models<\/h2>\r\n  <h3>Differential Pressure Switches<\/h3>\r\n  <p>Types J400K, J402K, H400K, and H402K measure the pressure difference between two points. Ranges start at 1 to 7 inches of water column differential (model 540) and reach 20 to 200 psid (model 547). Models 544 to 547 handle a working pressure up to 1,200 psi and a proof pressure of 2,500 psi.<\/p>\r\n  <p>With option M210, the switch shows the differential pressure on a gasketed window. The indicator accuracy is approximately 1.5% at 50% of range and 3% at the ends. For example, a filter housing can use one device to show the pressure drop and trip an alarm when the filter needs service. Our guide to <a href=\"https:\/\/swme.ae\/blog\/differential-pressure-transmitters-filter-monitoring-guide\/\" target=\"_blank\" rel=\"noopener\">differential pressure transmitters for filter monitoring<\/a> covers this use in more detail.<\/p>\r\n\r\n  <h3>Temperature Switches<\/h3>\r\n  <p>Immersion stem models 120 and 121 use a nickel plated brass stem. Model 120 covers 0 to 225 \u00b0F (minus 18 to 107 \u00b0C). Model 121 covers 200 to 425 \u00b0F (93 to 218 \u00b0C). A 316L stainless steel stem is available as option M504.<\/p>\r\n  <p>Bulb and capillary models suit remote installations. They have a standard 6 foot, 304 stainless steel capillary and a non toxic oil fill. The F types cover minus 125 to 650 \u00b0F (minus 87 to 343 \u00b0C) depending on the model. Typical deadband is 1% for F types and 2% of range for B, C, and E types. Temperature setpoint repeatability is plus or minus 2% of full scale.<\/p>\r\n\r\n  <h2>Electrical Ratings and Switch Options<\/h2>\r\n  <p>All models are rated 15 A at 125, 250, and 480 VAC as standard. For DC loads, the ratings are 2 A resistive and 1 A inductive at 24 to 30 VDC, and 0.5 A resistive and 0.03 A inductive at 125 VDC. The VDC values come from testing and experience. They are not UL rated.<\/p>\r\n  <div class=\"tablewrap\">\r\n  <table class=\"compare\">\r\n    <tr><th>Option<\/th><th>Description<\/th><\/tr>\r\n    <tr><td class=\"tech\">0140<\/td><td>1 A gold contact at 125 VAC<\/td><\/tr>\r\n    <tr><td class=\"tech\">0500<\/td><td>5 A close deadband at 125 and 250 VAC<\/td><\/tr>\r\n    <tr><td class=\"tech\">1010<\/td><td>10 A DPDT at 125 and 250 VAC<\/td><\/tr>\r\n    <tr><td class=\"tech\">1070<\/td><td>10 A at 125 VDC<\/td><\/tr>\r\n    <tr><td class=\"tech\">1520<\/td><td>15 A adjustable deadband at 125, 250, and 277 VAC<\/td><\/tr>\r\n    <tr><td class=\"tech\">1530<\/td><td>15 A external manual reset at 125, 250, and 480 VAC (latches on rise only)<\/td><\/tr>\r\n    <tr><td class=\"tech\">1535<\/td><td>15 A high ambient option at 125, 250, and 480 VAC<\/td><\/tr>\r\n    <tr><td class=\"tech\">2000<\/td><td>20 A at 125, 250, and 480 VAC<\/td><\/tr>\r\n  <\/table>\r\n  <\/div>\r\n  <p><a href=\"https:\/\/www.instrumentationblog.in\/pressure-switch-setpoint-deadband-configuration\/\" target=\"_blank\" rel=\"noopener\">Deadband and minimum setpoint<\/a> can change with these options. Confirm the final values with us before you order.<\/p>\r\n\r\n  <h2>Specifications at a Glance<\/h2>\r\n  <div class=\"tablewrap\">\r\n  <table class=\"compare\">\r\n    <tr><th>Parameter<\/th><th>Specification<\/th><\/tr>\r\n    <tr><td class=\"tech\">Setpoint repeatability, pressure and differential pressure<\/td><td>Plus or minus 1% (models 440 to 457, 550 to 559); plus or minus 2% (models 126 to 376, 520 to 535, 540 to 547, 570 to 572, S126B to S164B); plus or minus 3% (models 610 to 614). Percent of full scale.<\/td><\/tr>\r\n    <tr><td class=\"tech\">Setpoint repeatability, temperature<\/td><td>Plus or minus 2% of full scale<\/td><\/tr>\r\n    <tr><td class=\"tech\">Ambient temperature limits<\/td><td>Minus 40 to 160 \u00b0F (minus 40 to 71 \u00b0C)<\/td><\/tr>\r\n    <tr><td class=\"tech\">Shock and vibration<\/td><td>Setpoint repeats after 15 G for 10 msec of shock, and after 2.5 G vibration from 5 to 500 Hz<\/td><\/tr>\r\n    <tr><td class=\"tech\">Ambient effect<\/td><td>Setpoint typically shifts less than 1% of range for a 50 \u00b0F (28 \u00b0C) ambient change<\/td><\/tr>\r\n    <tr><td class=\"tech\">Enclosure<\/td><td>Die cast aluminum, epoxy powder coated, gasketed, captive cover screws, NEMA 4X construction<\/td><\/tr>\r\n    <tr><td class=\"tech\">Electrical connection<\/td><td>One 3\/4 inch NPT connection and two 7\/8 inch knockouts<\/td><\/tr>\r\n    <tr><td class=\"tech\">Pressure connection<\/td><td>1\/4 inch NPT female on most models; 1\/2 inch on models 520 to 535 and S models; 1\/8 inch on models 540 to 547<\/td><\/tr>\r\n    <tr><td class=\"tech\">Weight<\/td><td>Approximately 3 to 7.5 lbs (1.4 to 3.4 kg), depending on model<\/td><\/tr>\r\n  <\/table>\r\n  <\/div>\r\n  <p class=\"note\">Full details are in the <a href=\"https:\/\/www.ueonline.com\/wp-content\/uploads\/400-B.pdf\" target=\"_blank\" rel=\"noopener\">400 Series datasheet<\/a>.<\/p>\r\n\r\n  <h2>Certifications for UAE and Global Projects<\/h2>\r\n  <p>FM approval covers all models as standard. Intrinsic safety certification is an option, and you must order the matching option code. For UAE projects, order option M463 for ECAS certified intrinsic safety, marked Ex ia IIC T6 Ga. The ATEX and IECEx marking is II 1 G Ex ia IIC T6 Ga for ambient temperatures from minus 50 to 60 \u00b0C.<\/p>\r\n  <div class=\"tablewrap\">\r\n  <table class=\"compare\">\r\n    <tr><th>Region<\/th><th>Certification<\/th><th>Option<\/th><\/tr>\r\n    <tr><td class=\"tech\">UAE<\/td><td>ECAS Ex ia IIC T6 Ga<\/td><td>M463<\/td><\/tr>\r\n    <tr><td class=\"tech\">Europe and International<\/td><td><a href=\"https:\/\/en.wikipedia.org\/wiki\/ATEX_directive\" target=\"_blank\" rel=\"noopener\">ATEX<\/a> and IECEx Ex ia; also PED 2014\/68\/EU and LVD 2014\/35\/EU<\/td><td>M405<\/td><\/tr>\r\n    <tr><td class=\"tech\">North America<\/td><td>FM approved (all models); UL listed (400 and 402), UL recognized (403); UL 508 and UL 873<\/td><td>Standard<\/td><\/tr>\r\n    <tr><td class=\"tech\">United Kingdom<\/td><td>UKCA Ex ia<\/td><td>M462<\/td><\/tr>\r\n    <tr><td class=\"tech\">India<\/td><td>PESO\/CCOE Ex ia IIC T6 Ga<\/td><td>M405<\/td><\/tr>\r\n    <tr><td class=\"tech\">Brazil, China, and EAC<\/td><td>INMETRO, CCC\/NEPSI, and EAC Ex<\/td><td>M391, M408, M406<\/td><\/tr>\r\n  <\/table>\r\n  <\/div>\r\n  <p>These certificates cover <a href=\"https:\/\/en.wikipedia.org\/wiki\/Intrinsic_safety\" target=\"_blank\" rel=\"noopener\">intrinsic safety<\/a> only. Confirm your loop and barrier design for each installation. Our guide to <a href=\"https:\/\/swme.ae\/blog\/pressure-measurement-hazardous-areas\/\" target=\"_blank\" rel=\"noopener\">pressure measurement in hazardous areas<\/a> explains zones and protection methods.<\/p>\r\n\r\n  <h2>Typical Applications for the 400 Series<\/h2>\r\n  <p>UE highlights industrial gas production and the control of assets such as pumps, turbines, and compressors. The range also serves water and wastewater, power, and OEM equipment.<\/p>\r\n  <ul class=\"app-list\">\r\n    <li>Low and high pressure trips on pump suction and discharge lines, as covered in our article on <a href=\"https:\/\/swme.ae\/blog\/pump-protection-pressure-flow-temperature-instruments\/\" target=\"_blank\" rel=\"noopener\">pump protection using pressure, flow, and temperature instruments<\/a><\/li>\r\n    <li>Compressor and turbine protection with pressure and temperature trips<\/li>\r\n    <li>Industrial gas production and regulation<\/li>\r\n    <li>Water and wastewater treatment plants<\/li>\r\n    <li>Power generation plants, including lube oil and cooling circuits<\/li>\r\n    <li>Filter monitoring with differential pressure models<\/li>\r\n    <li>OEM skids and packaged equipment<\/li>\r\n  <\/ul>\r\n\r\n  <h2>How to Order a 400 Series Switch<\/h2>\r\n  <p>Build the part number from three choices: type, model, and options. For example, a one switch pressure unit with hex screw adjustment is type J400. Pair it with model 551, a diaphragm sensor with Teflon, Viton, and 316L SS wetted parts for 0 to 80 inches of water column. Then add option M201 to have the factory set your setpoint.<\/p>\r\n  <p>To quote the right unit, we need the following details from you:<\/p>\r\n  <ul class=\"app-list\">\r\n    <li>Process fluid and its temperature<\/li>\r\n    <li>Pressure or temperature range, and the setpoint<\/li>\r\n    <li>Whether the switch should act on rising or falling values<\/li>\r\n    <li>Number of switches and the electrical load<\/li>\r\n    <li>Certification needed, such as option M463 for the UAE<\/li>\r\n  <\/ul>\r\n  <p>The 400 Series is a mechanical switch, so it does not provide diagnostics or a digital output. If you need a continuous signal instead, read <a href=\"https:\/\/www.instrumentationblog.in\/temperature-switch-vs-temperature-transmitter\/\" target=\"_blank\" rel=\"noopener\">when to use a temperature switch or a transmitter<\/a>. If you need those, our article on the <a href=\"https:\/\/swme.ae\/blog\/united-electric-controls-one-series\/\" target=\"_blank\" rel=\"noopener\">UE One Series electronic switch<\/a> covers that option. For safety loops, see the <a href=\"https:\/\/swme.ae\/blog\/ue-one-series-safety-transmitter\/\" target=\"_blank\" rel=\"noopener\">UE One Series Safety Transmitter<\/a>.<\/p>\r\n\r\n  <h2>UE 400 Series Suppliers in UAE and Gulf<\/h2>\r\n  <p>SWME Control Systems Trading LLC supplies the United Electric Controls 400 Series to oil and gas, power, water, and OEM customers across the UAE, Qatar, Oman, Kuwait, and Bahrain. Our team helps you choose the right type, range, and options for your process.<\/p>\r\n  <p>You can see our standard <a href=\"https:\/\/www.swme.ae\/PressureSwitch.php\" target=\"_blank\" rel=\"noopener\">pressure switches<\/a> and <a href=\"https:\/\/www.swme.ae\/TemperatureSwitches.php\" target=\"_blank\" rel=\"noopener\">temperature switches<\/a> on our product pages. For filter and pump duty, we also supply <a href=\"https:\/\/www.swme.ae\/DifferentialPS.php\" target=\"_blank\" rel=\"noopener\">differential pressure switches<\/a>.<\/p>\r\n  <p>For the full manufacturer description, visit the UE page for the <a href=\"https:\/\/www.ueonline.com\/all-products\/400-series-pressure-and-temperature-switch\/\" target=\"_blank\" rel=\"noopener\">400 Series Pressure and Temperature Switch<\/a>. You can also read more about the working principle of a <a href=\"https:\/\/en.wikipedia.org\/wiki\/Pressure_switch\" target=\"_blank\" rel=\"noopener\">pressure switch<\/a>. More application notes are available in our <a href=\"https:\/\/swme.ae\/blog\/category\/pressure\/\" target=\"_blank\" rel=\"noopener\">pressure measurement articles<\/a>.<\/p>\r\n  <p>To discuss your application or request a quotation, contact our team through the <a href=\"https:\/\/swme.ae\/ContactUs.php\" target=\"_blank\" rel=\"noopener\">contact page<\/a>.<\/p>\r\n\r\n  <h2>400 Series Frequently Asked Questions<\/h2>\r\n  <details class=\"criterion\" open>\r\n    <summary>What is the difference between J type and H type switches?<\/summary>\r\n    <p>J types use an internal hex screw to adjust the setpoint. H types use an internal adjustment with a reference dial, which makes it easier to set a value without a separate gauge.<\/p>\r\n  <\/details>\r\n  <details class=\"criterion\" open>\r\n    <summary>Can the 400 Series be used in hazardous areas?<\/summary>\r\n    <p>Yes, when you order the intrinsic safety option for your region. For UAE projects, that is option M463 (ECAS). Confirm your loop and barrier design for the installation.<\/p>\r\n  <\/details>\r\n  <details class=\"criterion\" open>\r\n    <summary>Does the 400 Series need a power supply?<\/summary>\r\n    <p>No. It is a mechanical switch, so it senses pressure or temperature without power. The contacts only carry the circuit current from your system, up to the rated values.<\/p>\r\n  <\/details>\r\n  <details class=\"criterion\" open>\r\n    <summary>Is oxygen service available?<\/summary>\r\n    <p>Yes, on selected models. Option M550 provides O2 service cleaning in accordance with ASTM G93. The O ring, diaphragm material, and pressure connection can change, so deadband, low end of range, and ambient limits may be affected.<\/p>\r\n  <\/details>\r\n\r\n  <div class=\"cta-buttons\">\r\n    <a class=\"btn btn-whatsapp\" href=\"https:\/\/wa.me\/971529972726\" target=\"_blank\" rel=\"noopener\">Get Quote on WhatsApp<\/a>\r\n    <a class=\"btn btn-call\" href=\"tel:+971529972726\">Call for Price: +971 5299 72726<\/a>\r\n  <\/div>\r\n\r\n  <div class=\"inquiry-form\">\r\n    <h3>\ud83d\udccb Request Detailed Information<\/h3>\r\n    <label>Your Name <span class=\"required\">*<\/span><\/label>\r\n    <input type=\"text\" placeholder=\"Enter your name\">\r\n    <label>Your Email <span class=\"required\">*<\/span><\/label>\r\n    <input type=\"email\" placeholder=\"Enter your email\">\r\n    <label>Phone Number <span class=\"required\">*<\/span><\/label>\r\n    <input type=\"text\" placeholder=\"Enter your phone number\">\r\n    <label>Company Name<\/label>\r\n    <input type=\"text\" placeholder=\"Enter your company name\">\r\n    <label>Your Message \/ Requirements<\/label>\r\n    <textarea placeholder=\"Tell us about your process, range, setpoint, and certification needs...\"><\/textarea>\r\n    <button class=\"submit-btn\" type=\"button\">\ud83d\udce8 Send Inquiry<\/button>\r\n  <\/div>\r\n\r\n<\/div>\r\n<\/body>\r\n<\/html>\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t<div class='epvc-post-count'><span class='epvc-eye'><\/span>  <span class=\"epvc-count\"> 168<\/span><span class='epvc-label'> Views<\/span><\/div>","protected":false},"excerpt":{"rendered":"<p>&nbsp; Product Guide \u2022 Pressure and Temperature Switches UE 400 Series Pressure and Temperature Switch Suppliers in UAE SWME Control Systems Trading LLC \u2022 United Electric Controls \u2022 October 2026 Every process plant needs a dependable way to raise an alarm or shut down equipment when pressure or temperature moves outside safe limits. The 400 [&hellip;]<\/p>\n","protected":false},"author":2,"featured_media":964,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[25],"tags":[],"class_list":["post-952","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-pressure"],"_links":{"self":[{"href":"https:\/\/swme.ae\/blog\/wp-json\/wp\/v2\/posts\/952","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/swme.ae\/blog\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/swme.ae\/blog\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/swme.ae\/blog\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/swme.ae\/blog\/wp-json\/wp\/v2\/comments?post=952"}],"version-history":[{"count":12,"href":"https:\/\/swme.ae\/blog\/wp-json\/wp\/v2\/posts\/952\/revisions"}],"predecessor-version":[{"id":966,"href":"https:\/\/swme.ae\/blog\/wp-json\/wp\/v2\/posts\/952\/revisions\/966"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/swme.ae\/blog\/wp-json\/wp\/v2\/media\/964"}],"wp:attachment":[{"href":"https:\/\/swme.ae\/blog\/wp-json\/wp\/v2\/media?parent=952"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/swme.ae\/blog\/wp-json\/wp\/v2\/categories?post=952"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/swme.ae\/blog\/wp-json\/wp\/v2\/tags?post=952"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}